ANEST IWATA Corporation
CHINESE CHINESE JAPANESE JAPANESE contact us contact us site map site map
Products Solutions Company Profile IR Information HOME
HOME >> Products >> Compressors >> Compressor >> Oil-Package
Compressors Products Information

Your clean partner
Point
· Pressure switch type has a simple pressure switch control.
· 11kW is a manual dual control type.
· All more are equipped with oil alarm as standard.

Option

*Some models may not be available for sales in certain countries.
Features
COMG embodies high standards in basic performance, durability, safety, versatility and easy maintenance.
· All models are equipped with totally-enclosed motors which prevent motor problems such as damage to bearings by dust or insulation deteoriation by moisture.

High performance for professional use
· The two-way cooling system effectively releases compression heat (for 2.2kW and above).
· . A microcomputer ,remote control and group control is available as optional.A remote control and group control kit available as optional.

Energy-saving and economical.
· Automatic start-stop operation by the pressure switch.
Specifications of lubricating type packaged air compressors
1.5kW

Model
Item CLP15C-8.5

CLP15C-8.5D

(with air dryer)

Motor rated output
(kW{PS})
1.5{2}
Operation control system
pressure switch
Control pressure
(MPa)
0.7 0.85
Free air delivery
(L/min)
165
Air receiver capacity
(L)
25
Air outlet
(B)
G 1/4×1 ball cock
Rotating speed
(min-1(rpm))
1240
Air dryer Dew point at air outlet
(°C)
- Max. 15 (under pressure)
Refrigerant - HFC407C
External dimensions
((W×L×H)(mm))
693×585×840 693×585×1000
Mass
(kg)
86 102
Noise level(1.5m from front)
(dB(A))
53

2.2kW

Model
Item CLP22C-8.5 CLP22C-8.5D
(with air dryer)
CLP22C-14 CLP22C-14D
(with air dryer)
Motor rated output
(kW{PS})
2.2{3}
Operation control system
pressure switch
Control pressure
(MPa)
0.7 0.85 1.15 1.4
Free air delivery
(L/min)
275 235
Air receiver capacity
(L)
39
Air outlet
(B)
Rc 3/8×1 ball valve
Rotating speed
(min-1(rpm))
1100 920
Air dryer Dew point at air outlet
(°C)
- Max 15 (under pressure) - Max 15 (under pressure)
Refrigerant - HFC134a - HFC134a
External dimensions
((W×L×H)(mm))
890×655×
985
890×655×
1120
890×655×
985
890×655×
1200
Mass
(kg)
136 153 141 165
Noise level(1.5m from front)
(dB(A))
51

3.7kW

Model
Item CLP37C-8.5 CLP37C-8.5D
(with air dryer)
CLP37C-14 CLP37C-14D
(with air dryer)
Motor rated output
(kW{PS})
3.7{5}
Operation control system
pressure switch
Control pressure
(MPa)
0.7 0.85 1.15 1.4
Free air delivery
(L/min)
415 390
Air receiver capacity
(L)
39
Air outlet
(B)
Rc 3/8×1 ball valve
Rotating speed
(min-1(rpm))
1050 1150
Air dryer Dew point at air outlet
(°C)
- Max. 15 (under pressure) - Max. 15
(under pressure)
Refrigerant - HFC134a - HFC134a
External dimensions
((W×L×H)(mm))
890×655×
985
890×655×
1200
890×655×
985
890×655×
1200
Mass
(kg)
140 175 150 175
Noise level(1.5m from front)
(dB(A))
54

5.5kW

Model
Item CLP55C-8.5 CLP55C-8.5D
(with air dryer)
CLP55C-14 CLP55C-14D
(with air dryer)
Motor rated output
(kW{PS})
5.5{7.5}
Operation control system
pressure switch
Control pressure
(MPa)
0.7 0.85 1.15 1.4
Free air delivery
(L/min)
605 570
Air receiver capacity
(L)
70
Air outlet
(B)
Rc 3/4×1 ball valve
Rotating speed
(min-1(rpm))
1110 1010
Air dryer Dew point at air outlet
(°C)
- Max. 15 (under pressure) - Max. 15 (under pressure)
Refrigerant - HFC134a - HFC134a
External dimensions
((W×L×H)(mm))
1170×745×
1100
1170×745×
1530
1170×745×
1100
1170×745×
1530
Mass
(kg)
240 311 240 311
Noise level(1.5m from front)
(dB(A))
56

7.5kW

Model
Item CLP75C-8.5 CLP75C-8.5D
(with air dryer)
CLP75C-14 CLP75C-14D
(with air dryer)
Motor rated output
(kW{PS})
7.5{11}
Operation control system
pressure switch
Control pressure
(MPa)
0.7 0.85 1.15 1.4
Free air delivery
(L/min)
845 740
Air receiver capacity
(L)
70
Air outlet
(B)
Rc 3/4×1 ball valve
Rotating speed
(min-1(rpm))
960 860
Air dryer Dew point at air outlet
(°C)
- Max 15 (under pressure) - Max. 15 (under pressure)
Refrigerant - HCFC134a - HCFC134a
External dimensions
((W×L×H)(mm))
1230×870×
1100
1230×870×
1480
1230×870×
1100
1230×870×
1495
Mass
(kg)
305 380 305 380
Noise level(1.5m from front)
(dB(A))
56

11kW

Model
Item CLP110B-8.5 CLP110B-8.5D
(with air dryer)
CLP110B-14 CLP110B-14D
(with air dryer)
Motor rated output
(kW{PS})
11{15}
Operatinon control system
manual dual
Control pressure
(MPa)
0.7 0.85 1.15 1.4
Free air delivery
(L/min)
1215 1075
Air receiver capacity
(L)
75
Air outlet
(B)
Rc 3/4×1 ball valve
Rotating speed
(min-1(rpm))
1100 970
Air dryer Dew point at air outlet
(°C)
- Max. 15 (under pressure) - Max. 15 (under pressure)
Refrigerant - HFC134a - HFC134a
External dimensions
((W×L×H)(mm))
1230×870×
1115
1230×870×
1495
1230×870×
1115
1230×870×
1495
Mass
(kg)
340 415 340 415
Noise level(1.5m from front)
(dB(A))
59

*
1. Free air delivery means average discharge air volume at max. operating pressure which is converted into atmospheric pressure. It is not a warranted figure. Specific warranted figure will be available upon request. 
*
2. Noise level is measured in an anechoic room during full loaded operation.
* 3.

Dimensions are outer dimensions of the package that exclude extruding portions.

Compressors TOP
Product Lineup
Compressor
Recipro
Scroll
Screw
Options
Dryers
Reference
Conversion chart
PAGE TOP PAGE TOP
copyright (c) 2004 ANEST IWATA Corporation All rights reserved.