Pressure
switch type has a simple pressure switch control.
·
11kW is a manual
dual control type.
·
All more are equipped
with oil alarm as standard.
*Some models may not be
available for sales in certain countries.
Features
COMG embodies
high standards in basic performance, durability,
safety, versatility and easy maintenance.
·
All models
are equipped with totally-enclosed motors which
prevent motor problems such as damage to bearings
by dust or insulation deteoriation by moisture.
High
performance for professional use
·
The two-way cooling system
effectively releases compression heat (for 2.2kW
and above).
·
. A microcomputer ,remote control and
group control is available as optional.A remote
control and group control kit available as optional.
Energy-saving
and economical.
·
Automatic
start-stop operation by the pressure switch.
Specifications
of lubricating type packaged air compressors
1.5kW
Model
Item
CLP15C-8.5
CLP15C-8.5D
(with
air dryer)
Motor rated output
(kW{PS})
1.5{2}
Operation control
system
pressure switch
Control pressure
(MPa)
0.7
0.85
Free air delivery
(L/min)
165
Air receiver capacity
(L)
25
Air outlet
(B)
G 1/4×1 ball
cock
Rotating speed
(min-1(rpm))
1240
Air
dryer
Dew point at air
outlet
(°C)
-
Max. 15 (under pressure)
Refrigerant
-
HFC407C
External dimensions
((W×L×H)(mm))
693×585×840
693×585×1000
Mass
(kg)
86
102
Noise level(1.5m
from front)
(dB(A))
53
2.2kW
Model
Item
CLP22C-8.5
CLP22C-8.5D
(with air dryer)
CLP22C-14
CLP22C-14D
(with air dryer)
Motor rated output
(kW{PS})
2.2{3}
Operation control
system
pressure switch
Control pressure
(MPa)
0.7
0.85
1.15
1.4
Free air delivery
(L/min)
275
235
Air receiver capacity
(L)
39
Air outlet
(B)
Rc 3/8×1 ball
valve
Rotating speed
(min-1(rpm))
1100
920
Air
dryer
Dew point at air
outlet
(°C)
-
Max 15 (under pressure)
-
Max 15 (under pressure)
Refrigerant
-
HFC134a
-
HFC134a
External dimensions
((W×L×H)(mm))
890×655×
985
890×655×
1120
890×655×
985
890×655×
1200
Mass
(kg)
136
153
141
165
Noise level(1.5m
from front)
(dB(A))
51
3.7kW
Model
Item
CLP37C-8.5
CLP37C-8.5D
(with air dryer)
CLP37C-14
CLP37C-14D
(with air dryer)
Motor rated output
(kW{PS})
3.7{5}
Operation control
system
pressure switch
Control pressure
(MPa)
0.7
0.85
1.15
1.4
Free air delivery
(L/min)
415
390
Air receiver capacity
(L)
39
Air outlet
(B)
Rc 3/8×1 ball
valve
Rotating speed
(min-1(rpm))
1050
1150
Air
dryer
Dew point at air
outlet
(°C)
-
Max. 15 (under pressure)
-
Max. 15
(under pressure)
Refrigerant
-
HFC134a
-
HFC134a
External dimensions
((W×L×H)(mm))
890×655×
985
890×655×
1200
890×655×
985
890×655×
1200
Mass
(kg)
140
175
150
175
Noise level(1.5m
from front)
(dB(A))
54
5.5kW
Model
Item
CLP55C-8.5
CLP55C-8.5D
(with air dryer)
CLP55C-14
CLP55C-14D
(with air dryer)
Motor rated output
(kW{PS})
5.5{7.5}
Operation control
system
pressure switch
Control pressure
(MPa)
0.7
0.85
1.15
1.4
Free air delivery
(L/min)
605
570
Air receiver capacity
(L)
70
Air outlet
(B)
Rc 3/4×1 ball
valve
Rotating speed
(min-1(rpm))
1110
1010
Air
dryer
Dew point at air
outlet
(°C)
-
Max. 15 (under pressure)
-
Max. 15 (under pressure)
Refrigerant
-
HFC134a
-
HFC134a
External dimensions
((W×L×H)(mm))
1170×745×
1100
1170×745×
1530
1170×745×
1100
1170×745×
1530
Mass
(kg)
240
311
240
311
Noise level(1.5m
from front)
(dB(A))
56
7.5kW
Model
Item
CLP75C-8.5
CLP75C-8.5D
(with air dryer)
CLP75C-14
CLP75C-14D
(with air dryer)
Motor rated output
(kW{PS})
7.5{11}
Operation control
system
pressure switch
Control pressure
(MPa)
0.7
0.85
1.15
1.4
Free air delivery
(L/min)
845
740
Air receiver capacity
(L)
70
Air outlet
(B)
Rc 3/4×1 ball
valve
Rotating speed
(min-1(rpm))
960
860
Air
dryer
Dew point at air
outlet
(°C)
-
Max 15 (under pressure)
-
Max. 15 (under pressure)
Refrigerant
-
HCFC134a
-
HCFC134a
External dimensions
((W×L×H)(mm))
1230×870×
1100
1230×870×
1480
1230×870×
1100
1230×870×
1495
Mass
(kg)
305
380
305
380
Noise level(1.5m
from front)
(dB(A))
56
11kW
Model
Item
CLP110B-8.5
CLP110B-8.5D
(with air dryer)
CLP110B-14
CLP110B-14D
(with air dryer)
Motor rated output
(kW{PS})
11{15}
Operatinon control
system
manual dual
Control pressure
(MPa)
0.7
0.85
1.15
1.4
Free air delivery
(L/min)
1215
1075
Air receiver capacity
(L)
75
Air outlet
(B)
Rc 3/4×1 ball
valve
Rotating speed
(min-1(rpm))
1100
970
Air
dryer
Dew point at air
outlet
(°C)
-
Max. 15 (under pressure)
-
Max. 15 (under pressure)
Refrigerant
-
HFC134a
-
HFC134a
External dimensions
((W×L×H)(mm))
1230×870×
1115
1230×870×
1495
1230×870×
1115
1230×870×
1495
Mass
(kg)
340
415
340
415
Noise level(1.5m
from front)
(dB(A))
59
*
1.
Free air delivery means
average discharge air volume at max. operating pressure
which is converted into atmospheric pressure. It
is not a warranted figure. Specific warranted figure
will be available upon request.
*
2.
Noise level is measured
in an anechoic room during full loaded operation.
*
3.
Dimensions
are outer dimensions of the package that exclude