Compressed air extracted
from air compressor contains lots of hot moisture. If
such compressed air is used as it is, it will cause trouble
in compressed air equipment.
The refrigerated air dryer is a forced air-cooled type
which cools incoming compressed air down to pressure dew
point of 10°C, while moisture is condensed and separated.
*A
limited number of products cannot be sold in certain
countries.
Model
Item
RDG-22
RDG-37
RDG-55
Air
condition
Ambient temperature
(°C)
32
Inlet
air temperature
(°C)
Air flow
50/60Hz
(m3/min)
40
-
-
-
45
0.31/0.35
0.5/0.55
0.74/0.81
50
0.31/0.35
0.5/0.55
0.74/0.81
55
0.31/0.35
0.5/0.55
0.74/0.81
60
0.29/0.33
0.48/0.52
0.70/0.77
Inlet air temperature
(°C)
5
8
Inlet air pressure
(MPa)
0.2
1.6
Dew point at air
outlet
(°C)
10
Refrigerant
HCFC22
Air outlet connection
(B)
Rc 3/8
Rc 3/8
Rc 1/2
Mass
(kg)
30
32
38
Dimensions
((W×L×H)(mm))
300×380×790
300×380×790
350×430×820
Electric consumption
((50/60Hz)(kW))
0.17/0.18
0.22/0.23
0.25/0.30
Model
Item
RDG-75
RDG-110
RDG-150
RDG-220
RDG-370
Air
condition
Ambient temperature
(°C)
32
Inlet air temperature
(°C)
Air flow
50/60Hz
(m3/min)
40
-
-
-
-
-
45
1.2/1.3
1.65/1.82
2.8/3.1
3.9/4.3
6.6/7.3
50
1.2/1.3
1.65/1.82
2.8/3.1
3.9/4.3
6.6/7.3
55
1.2/1.3
1.65/1.82
2.8/3.1
3.9/4.3
6.6/7.3
60
1.14/1.24
1.57/1.73
2.66/2.95
3.71/4.09
6.27/6.94
Inlet air temperature
(°C)
5
80
Inlet air pressure
(MPa)
0.2
1.6
Dew point at air
outlet
(°C)
10
Refrigerant
HCFC22
Air outlet connection
(B)
Rc 3/4
Rc 1
Rc 1 1/2
Mass
(kg)
42
56
75
89
120
Dimensions
((W×L×H)(mm))
350×
430×
820
420×
450×
960
420×
520×
1040
420×
610×
1120
480×
670×
1170
Electric consumption
((50/60Hz)(kW))
0.35/0.41
0.48/0.56
0.96/1.16
1.30/1.55
2.2/2.7
Model
Item
GT7055
GT7075
GT7095
GT7120
GT7150
Air
condition
Ambient temperature
(°C)
32
Inlet air temperature
(°C)
Air flow
50/60Hz
(m3/min)
40
9.6/10.6
13/14.3
16/18.8
20/23.5
25/30
45
7.97/8.80
10.8/11.9
13.3/15.6
16.6/19.5
20.8/24.9
50
6.53/7.21
8.84/9.72
10.9/12.8
13.6/16.0
17.0/20.4
55
5.47/6.04
7.41/8.15
9.12/10.7
11.4/13.4
14.3/17.1
60
4.61/5.09
6.24/6.86
7.68/9.02
9.6/11.3
12.0/14.4
Inlet air temperature
(°C)
2
60
Inlet air pressure
(MPa)
0.2
1.0
Dew point at air
outlet
(°C)
10
Refrigerant
HFC407C
Air outlet connection
(B)
Rc 2(union)
RC 2 1/2 (flange)
RC 3 (flange)
Mass
(kg)
115
140
230
360
Dimensions
((W×L×H)(mm))
500×
1000×
950
550×
1100×
980
600×
1250×1100
700×
1450×
1300
Electric consumption
((50/60Hz)(kW))
1.3/1.5
1.6/2.0
2.1/2.6
2.4/2.9
3.5/4.4
*1.
In order to
get air flow capacity in case of 38 °C ambient
temperature, multiply the above figure by 0.88 for
RDG series and by 0.92 for GT series.
*2.
The air flow
capacity is at 0.7MPa. In case of 0.6MPa, multiply
the above figure by 0.94 for RDG series and by 0.95
for GT series.
*3.
Pressure drop
is related to air flow characteristics. Detailed
information will be given separately on request.
*4.
Recommended
ambient temperature is 2
43°C
*5.
We have optional
models GT5055/5075 which are for high temperature
intake air to cover 55/75kW range.