They can filter fine oil particles of up to 0.1PPM2/W(0.12mg/m3).
Specifications of Micro-Alescer
Model
Item
NAF-302
NAF-602
(M4000-10-F1)
(M8000-10-F1)
Connection
Rc 1/4
Rc 3/8
Rc 3/4
Drain system
automatic
manual
automatic
Air flow
(L/min)
825
2600
Filtration
(µm)
0.1
Operating pressure
(MPa)
1.0
Operating temperature range(fluid
temperature)
(°C)
5
54
Mass
(kg)
0.52
1.35
Remarks
Pressure drop at the
above air flow is 0.01MPa and less at 0.69 Mpa on
primary side.
Models shown by parentheses are those
which are recommended (made by CKD Corporation).
*
(1)
Auto
drain type is activated at a point less than an
internal pressure of 0.1MJPa (1kgf/cm2)
and closes at a point over 0.1MPa (1kgf/cm2).
(2)
Use air
compressor of over 0.75kW since it needs over
90 liters/min.
(3)
Use manual drain type with air compressor
of less than 0.75kW.
(4)
Bowls are made of polycarbonate. Do
not use chemicals such as thinner, carbon tetrachloride,
alcohol, chloroform, trichloroethlyene, acetate,
sulfuric acid, alkaline water solution in surrounding
atmosphere.
(5)
Do not use these products when air
compressor uses synthetic oil. If done, it can break
polycarbonate bowl.